Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator (thermopile) and the top ¹⁄₈" min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports. See Figure 17.
To light the burner, refer to the lighting instruc- tions on Page 18.
MILLIVOLT PILOT ASSEMBLY | ||
Proper Pilot Flame | Hood | Igniter Rod |
Appearance |
|
|
Thermocouple |
| 3/8" Min. |
|
| |
|
| (9 mm) |
Pilot |
|
|
Nozzels |
|
|
Thermopile |
| |
Figure 17 |
|
|
Electronic Appliance Checkout
To light the burner, refer to the lighting instruc- tions on Pagex 19. Ensure the igniter lights the
Electronic Wiring Diagram (Honeywell)
1.If any of the original wire as supplied must be replaced,
1.it must be replaced with Type AWM 105°C – 18 GA. wire.
2.120V, 60Hz – Less than 3 amps.
|
| *Leave the ON/OFF switch, which is integral | ||||
*ON/OFF Switch (Integral | with the gas valve, in the ON position. | |||||
with Gas Valve) |
| Outlet Box Green |
| |||
|
|
|
| |||
| Gas Valve | PILOT |
| Ground Screw |
| |
|
|
|
| G |
| |
|
| ASSEMBLY |
| 120 | ||
| IGNITER |
|
| |||
|
|
|
| W | ||
BK |
|
|
|
| BK | VAC. |
|
|
|
|
| ||
|
|
|
|
|
| |
| R |
|
|
|
|
|
| BL |
|
|
|
|
|
|
|
|
| G | White Wire | |
|
|
|
|
| ||
|
|
|
|
| To Opposite | |
|
|
|
|
| Side | |
|
|
|
|
| Junction Box | |
|
| W |
|
| Transf. |
|
|
| B |
|
|
| |
|
| G |
|
| 120 V. |
|
Hot side of Outlet
BL | 24 V |
| |
R |
|
WT | BK |
|
WT
SPILL SWITCH (high limit disc)
*Optional Control Switches - OFF/ON wall switch or remote control receiver.
Schematic Represen- |
|
|
tation Only |
| Field Wired |
Figure 19 |
| Factory |
| ||
|
| Wired |
WARRANTY
Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the war- ranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu- ments for future reference.
REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer. Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1.The model number of the appliance.
2.The serial number of the appliance.
3.The part number.
4.The description of the part.
5.The quantity required.
6.The installation date of the appliance.
If you encounter any problems or have any ques- tions concerning the installation or application of this system, please contact your distributor, or Lennox directly:
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, CA 92865
pilot. The pilot flame should engulf the flame sensor as shown in Figurex 18.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
ELECTRONIC PILOT ASSEMBLY | ||
Proper Pilot Flame Appearance | ||
Proper Flame | 3/8" to 1/2" | |
(9 | ||
Adjustment | ||
| ||
Pilot |
| |
Nozzels | Ground | |
| ||
| Electrode | |
| Flame Rod |
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM105 C - 18 gage wire.
*Optional Control Switches - OFF/ON wall switch or remote control receiver.
Note: Turn the
Schematic Represen- tation Only
White |
|
|
SpillSwitch | TP | TH TP |
TH | ||
| Thermopile |
|
White |
|
|
| Black | Field Wired |
|
|
14
Hot Surface |
Igniter |
Figure 18 |
Withpropercareandmaintenance,yourappliance willprovidemanyyearsofenjoyment.Ifyoushould experience any problem, first refer to the trouble shootingguideinthismanual.Ifproblempersists, contact your Lennox distributor.
WIRING DIAGRAMS
Wiring diagrams are provided here for refer- ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
| * Optional Control Switch |
|
| Factory | |
|
|
| |||
Figure 20 |
|
|
|
| Wired |
| Appliance mounted OFF / ON Switch |
| |||
|
|
|
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fireplace. Please contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox dealer, please call
Your Fireplace's Model Number ________________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed___________________________
The Type of Gas Your Fireplace Uses ____________________________________
Your Dealer's Name ________________________________________________
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.