CONGRATULATIONS!
In selecting this LENNOX
Please carefully read and follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
Input (BTU)
Models | Fuel | Input Rate | |
| Type | (BTU / HR) | |
|
|
| |
Nat. Gas | 30,000 high | ||
23,000 low | |||
|
| ||
|
|
| |
Propane | 28,000 high | ||
22,000 low | |||
|
|
Table 1
Electronic Models -
TABLE OF CONTENTS |
|
|
Introduction | page | 2 |
General Information | page | 2 |
Gas Controls/Control Compartment, |
|
|
Access | page | 4 |
Operation/Care of Your Appliance | page | 4 |
Variable Flame Adjustment | page | 5 |
Venting Action and (spill switch) | page | 5 |
Outside Combustion Air Control | page | 6 |
Maintenance | page | 6 |
Front Glass Enclosure Panel, |
|
|
Removal and Installation | page | 7 |
Logs, Vermiculite & Ember Placement | page | 8 |
Burner Adjustments | page 10 | |
Maintenance Schedule | page 11 | |
Troubleshooting Guide – Millivolt | page 12 | |
Troubleshooting Guide – Electronic ... | page 12 | |
Millivolt Appliance Checkout | page 14 | |
Electronic Appliance Checkout | page 14 | |
Wiring Diagrams | page 14 | |
Warranty | page 14 | |
Product Reference Information | page 14 | |
Accessory Components | page 15 | |
Lighting Instructions – Millivolt | page 18 | |
Lighting Instructions – Electronic | page 19 | |
Replacement Parts List | page 20 |
INTRODUCTION
The millivolt appliances have a millivolt gas control valve witha piezo ignition system which provides safe, efficient operation.
The electronic appliances have an electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
LISTING AS FOLLOWS:
These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No.
-2000), and
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Electrical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
GENERAL INFORMATION
Note: Installation and repair should be per- formed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc.
IMPORTANT
It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean. See Maintenance instructions on Pagex 6.
Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. Locate furniture and window coverings accordingly.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dangerous.
Millivolt Models - BTU Input
Millivolt models come standard with the manu-
Electronic models have a fixed rate gas valve. Input of electronic models is shown in the following table:
Input (BTU) - Fixed Rate
(electronic models)
Models | Fuel | Input Rate |
| Type | (BTU / HR) |
Nat. Gas | 30,000 | |
|
|
|
Pro. Gas | 28,000 | |
(if field converted) |
|
|
Table 2
Gas Pressure -
Tables 3, 4 and 5 show the appliances' gas pressure requirements.
Inlet Gas Supply Pressure
(all models)
Fuel # |
|
| Minimum | Maximum | ||
|
|
|
|
|
|
|
Natural Gas |
| 5.0" WC | 10.5" WC | |||
| (1.24 kPa) | (2.61 kPa) | ||||
|
|
| ||||
|
|
|
|
|
|
|
Propane |
|
| 11.0" WC | 13.0" WC | ||
|
| (2.74 kPa) | (3.23 kPa) | |||
|
|
| ||||
Table 3 |
|
|
|
|
|
|
|
|
| ||||
Manifold Gas Supply Pressure | ||||||
|
| (millivolt models) | ||||
|
|
|
|
|
| |
Fuel # |
|
| Low |
| High | |
|
|
|
| |||
Natural | (Lo) 2.2" WC |
| (Hi) 3.5" WC | |||
Gas |
|
| (.55 kPa) |
| (.87 kPa) | |
|
|
|
| |||
Propane | (Lo) 6.3" WC |
| (Hi) 10.0" WC | |||
| (1.57 kPa) |
| (2.49 kPa) | |||
|
|
| ||||
Table 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Manifold Gas Supply Pressure | ||||||
| (electronic models) | |||||
Fuel # |
|
| Fixed | |||
|
|
|
|
|
|
|
Natural Gas |
|
| 3.5" WC | |||
|
| (.87 kPa) | ||||
|
|
|
|
|
| |
Propane |
|
| 10.0" WC | |||
|
| (2.49 kPa) | ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Table 5 |
|
|
|
|
|
|
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.