READ LOG WARNINGS ON PAGE 9 BEFORE PROCEEDING
1.Remove front glass enclosure panel from appliance.
a.Open Control Compartment Access Panel (see Control Compart- ment Access Instructions on Page 4.
b.Remove the glass panel enclosure (see Removing Glass Enclosure Panel instructions on Page 9.
2.Remove the following from firebox; log set, embers (rockwool) and vermiculite. Handle logs carefully to prevent breakage.
3. Ensure the Grate is properly installed in the firebox with the 4 legs of the grate fitting into the 4 dimples on the firebox floor.
4.
6.Placement of Glowing Embers -
Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 7 ). Keep the pieces fluffed up, not matted. Distribute these pieces over the surface of the burner, as shown in Figure 8. Do not use more than is necessary. Ensure that the main burner ports remain uncovered by the ember material.
Note: This appliance is provided with enough Glowing Embers for several applications, do not use all that is in a new bag at one time. For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (order Catalog Number 88L53).
Place Embers on burner as shown.
Figure 8 | DO NOT PLACE EMBERS OVER |
| GAS PORTS / AREAS CIRCLED |
7.Place Log (A) on the grate as shown in Figure 9
A
Position Groove At The Bottom Of | Position The Groove At The Bottom Of | |
Log (A) Over The Grate And Slide It | ||
Log (A) Over The Log Support Here | ||
Forward Against The Grate Here | ||
|
(Valve Access Side)
Figure 9
8.Place Log (B) as shown in Figure 10.
| Position Log (B) Against The Back Of |
B | The Grate Here |
| |
| Position Groove at The Bottom Of Log (B) Over The Grate |
| Here And Slide It Against The Back Of The Grate |
Figure 10 | (Valve Access Side) |
|
9.Place Log (C) as shown in Figure 11.
Log (C) Lays Over Logs (A) and (B)
B
A
C | (Valve Access Side) |
| Position The Groove in The Back of Log (C) |
Figure 11 | Against The Grate |
10.Place Log (D) as shown in Figure 12.
Position And Slide Log (D) Against The
Back Of The Grate
A
| D |
(Valve Access Side) | Place Log (D) Over The |
| |
| Flat Spot On Log (A) Here |
Figure 12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9