Burn-in Period

Test gauge connections are provided on the front of the millivolt gas control valve, identified IN for the inlet and OUT for the manifold side (see Fig- urex 2 on Pagex 4 ). A 1/8" NPT Test gauge con- nection is provided at the inlet and outlet side of the electronic gas control valve (see Figurex 3 on Pagex 5).

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).

Orifice Sizes - Sea Level to High Altitude (All Models)

These appliances are tested and approved for installations at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 6 ). For elevations above 4500 feet, these appliances must be properly "derated" by the gas supplier or qualified service technician (usually done at the time of installation).

Note: Derated (definition) - Replacing burner orifice with a smaller one to reduce BTU input. The installation of this appliance must be accord- ing to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN1-B149.1 and .2 codes - latest edition.

Burner Orifice Sizes (all models)

Elevation

Natural

Propane

Gas

Gas

Feet (meters)

drill size (inches)

drill size (inches)

 

 

 

 

0-4500

#37 (.104") *

1.55 mm (.061")*

(0-1372)

24M1001 •

42M7901 •

 

 

 

*Standard size installed at factory

• Part /Cat. Number

Table 6

Burn-in Period

During the first few fires of this appliance there will be some odor due to the curing of paint and burning off of lubricants used in the manufacturing process.

Depending on your use, the burn-in period may take a few hours or a few days.

KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED BY THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.

A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during the first two weeks of use to prevent the film from baking on (making it very difficult to remove). See Glass Cleaning on Page 8.

SAFETY & WARNIING INFORMATION

Manual background WARNING

If the information in this manual is not followed exactly,a fireorexplosion may result causing prop- erty damage, personal injury or loss of life.

Manual background WARNING

Failure to comply with the instal- lation and operating instructions provided in this document will result in an improperly installed and operating appliance, voiding its warranty. Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appli- ance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

Manual background IMPORTANT

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

Manual background WARNING

Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliances and to replace any parts of the control system and any gas controls which have been under water.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Manual background WARNING

Do not attempt to alter or modify the construction of the appli- ance or its components. Any modification or alteration may void the warranty, certification and listings of this unit.

Manual background WARNING

Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Manual background WARNING

These fireplaces are vented heaters. Do not burn wood or other material in these appli- ances.

Manual background WARNING

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Manual background WARNING

Children and adults should be alerted to the hazards of high surface temperatures. Use caution around the appliance to avoid burns or clothing igni- tion. Young children should be carefully supervised when they are in the same room as the appliance.

Note: An Optional Screen Heat Guard for the glass is available (see Page 15 for ordering infor- mation).

3

Page 3
Image 3
Lennox International Inc MPB35ST-NM manual Burn-inPeriod