Symptom-to-FRU index

Error messages

 

 

 

 

 

 

Symptom or error

FRU or action, in sequence

 

 

 

 

Unsupported memory.

DIMM. Make sure to use supported

 

 

memory.

 

 

 

 

 

Device address conflict.

1.

Load “Setup Defaults” in the BIOS

 

 

 

Setup Utility.

 

 

2.

Backup battery.

 

 

3.

System board.

 

 

 

 

 

Allocation error for device.

1.

Load “Setup Defaults” in the BIOS

 

 

 

Setup Utility.

 

 

2.

Backup battery.

 

 

3.

System board.

 

 

 

 

 

Failing bits: nnnn.

1.

DIMM.

 

 

2.

System board.

 

 

 

 

 

Invalid system configuration data.

1.

DIMM.

 

 

2.

System board.

 

 

 

 

 

I/O device IRQ conflict.

1.

Load “Setup Defaults” in the BIOS

 

 

 

Setup Utility.

 

 

2.

Backup battery.

 

 

3.

System board.

 

 

 

 

 

Hibernation error.

1.

Restore the system configuration to

 

 

 

what it was before the computer

 

 

 

entered hibernation mode.

 

 

2.

If memory size has been changed,

 

 

 

re-create the hibernation file.

 

 

 

 

 

Fan error.

1.

Fan.

 

 

2.

Thermal grease.

 

 

3.

System board.

 

 

 

 

Thermal sensing error.

System board.

 

 

 

 

Authentication of system services failed.

The Predesktop Area in the HDD is

 

Press <Esc> to resume.

corrupted. Restore it from a recovery disc.

 

 

 

 

Cannot boot from any device.

Check the status of device which you want

 

 

to boot from.

 

 

Device not found.

 

 

1.

The device you want to boot from.

 

 

2.

System board.

 

 

Device Error.

 

 

1.

The device you want to boot from.

 

 

2.

System board.

 

 

No valid operating system.

 

 

1.

Check that the operating system has no

 

 

 

failure and is installed correctly.

 

 

2.

Reinstall the operation system.

 

 

Excluded from boot order.

 

 

v Enter the BIOS Setup Utility and add the

 

 

 

device in boot order.

 

 

 

 

Lenovo 3000 C200 37

Page 43
Image 43
Lenovo 3000 C200 manual Error messages, To boot from