Symptom-to-FRU index
The
Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to “Intermittent problems” on page 39.
Note
For a device not supported by diagnostic codes in the Lenovo 3000 notebook computers, see the manual for that device.
Numeric error codes
Symptom or error | FRU or action, in sequence | |
|
|
|
0200 | 1. | Reseat the hard disk drive. |
Failure Fixed Disk | 2. | Load Setup Defaults in BIOS Setup |
|
| Utility. |
| 3. | Hard disk drive. |
| 4. | System board. |
|
|
|
021x | 1. | Keyboard. |
Keyboard error | 2. | System board. |
|
| |
0220 | Load Setup Defaults in BIOS Setup Utility. | |
Monitor type does not match |
|
|
SETUP |
|
|
|
| |
0230 | System board. | |
Shadow RAM Failed at offset:nnnn |
|
|
|
|
|
0231 | 1. | DIMM. |
System RAM Failed at offset:nnnn | 2. | System board. |
|
|
|
0232 | 1. | DIMM. |
Extended RAM Failed at offset:nnnn | 2. | System board. |
|
|
|
0250 | 1. | Charge the backup battery for more |
System battery is |
| than 8 hours by connecting the ac |
SETUP |
| adapter. |
| 2. | Replace the backup battery and run BIOS |
|
| Setup Utility to reset the time and date. |
|
|
|
0251 | 1. | Charge the backup battery for more |
System CMOS checksum |
| than 8 hours by connecting the ac |
configuration use |
| adapter. |
| 2. | Replace the backup battery and run BIOS |
|
| Setup Utility to reset the time and date. |
|
|
|
Lenovo 3000 C200 35