Lenovo 3000 C200 manual Symptom-to-FRUindex, Symptom or error

Models: 3000 C200

1 104
Download 104 pages 44.52 Kb
Page 42
Image 42

Symptom-to-FRU index

Symptom or error

FRU or action, in sequence

 

 

 

0260

1.

Charge the backup battery for more

System timer error

 

than 8 hours by connecting the ac

 

 

adapter.

 

2.

Replace the backup battery and run BIOS

 

 

Setup Utility to reset the time and date.

 

3.

System board.

 

 

 

0270

1.

Charge the backup battery for more

Real time clock error

 

than 8 hours by connecting the ac

 

 

adapter.

 

2.

Replace the backup battery and run BIOS

 

 

Setup Utility to reset the time and date.

 

3.

System board.

 

 

 

0280

1.

Load “Setup Default” in BIOS Setup

Previous boot incomplete— Default

 

Utility.

configuration used

2.

DIMM.

 

3.

System board.

 

 

 

02F4

1.

Load Setup Defaults in BIOS Setup

EISA CMOS not writable

 

Utility.

 

2.

Replace the backup battery.

 

3.

System board.

 

 

 

02F5

1.

DIMM.

DMA test failed

2.

System board.

 

 

 

02F6

1.

DIMM.

Software NMI failed

2.

System board.

 

 

 

02F7

1.

DIMM.

Fail-safe timer NMI failed

2.

System board.

 

 

 

36MT 8922