Installation and

Calibration

DC-1 Digital Controller

Selecting LIMITER ADJUST in the Sub Peak Limiter menu invokes a calibration routine for setting the optimal peak level for your installation. Pressing SELECT routes low frequency calibration noise to the subwoofer output of the DC-1. A two-line display indicates the LIMITER LEVEL setting in dB on the top line with a bar at the bottom to indicate relative noise level. Press MENU and to adjust the noise level to the highest level that your equipment can reproduce without overload.

Be sure the limiter is set to ON before exiting. Press DONE to exit and automatically set the limiter to the level you have selected.

This menu allows you to set the level of attenuation used whenever the DC-1 MUTE function is engaged. In the Output Levels menu, attenuation levels of -10dB, -20dB, -30dB, -40dB, and FULL are available.

This control in the Output Levels menu allows you to select the volume at which the DC-1 will power on. You can choose from a range of -80 to +12dB, or elect to have the system power on at the last level used (LAST LVL).

This control in the Output Levels menu allows you to select the initial volume level for Zone 2. You can choose from a range of -80 to +12dB, or elect to have Zone 2 power on at the last level used (LAST LVL).

Keep in mind that the Sub Peak Limiter is separate from the Subwoofer level control in the Effect Adjust menus — one setting does not affect the other.

Mute Level

Power On Volume

Zone 2 Volume

31

Page 37
Image 37
Lexicon DC-1 owner manual Mute Level Power On Volume Zone 2 Volume