Lexmark 4076-0XX Operator Panel Service Check, Fru Or Procedure, Action, Diagnostic Information

Models: 4076-0XX

1 89
Download 89 pages 22.95 Kb
Page 25
Image 25

4076-0XX

Operator Panel Service Check

 

FRU OR PROCEDURE

ACTION

 

 

 

1

Power Supply

Disconnect J11 from the system

 

 

board and check the following volt-

 

 

ages on the power supply cable:

 

 

J11-1 to GND = +5V dc

 

 

J11-3 to GND = +24V dc

 

 

If you do not have correct voltage,

 

 

replace the power supply. Be sure to

 

 

unplug the machine before you recon-

 

 

nect the power supply to the system

 

 

board.

 

 

 

2

System Board

Turn the printer on. Check for +5 V dc

 

 

at test point CE/TP near the operator

 

 

panel connector on the system board

 

 

 

3

Operator Panel Cover

The operator panel cover actuates

 

 

the operator panel sensor on the

 

 

operator panel. Check the cover for

 

 

any broken parts. Check the operator

 

 

panel sensor for dirt.

 

 

 

4

Operator Panel Card

Check the operator panel cable for

 

Operator Panel Cable

continuity. If the cable is good,

 

 

replace the operator panel. If the

 

 

symptom remains, replace the sys-

 

 

tem board.

 

 

 

Diagnostic Information 13

Page 25
Image 25
Lexmark 4076-0XX manual Operator Panel Service Check, Fru Or Procedure, Action, Diagnostic Information