CONTENTS
1. PREFACE |
|
1.1 SPECIFICATIONS | 3 |
1.2 FEATURES AND BENEFITS | 4 |
1.3 CONTROL LOCATIONS | 6 |
1.4 ADDITIONAL CONTROLS | 7 |
2. DISASSEMBLY INSTRUCTIONS |
|
2.1 MECHANICAL PARTS | 9 |
2.1.1 FRONT GRILLE | 9 |
2.1.2 CONTROL BOX | 10 |
2.1.3 CONTROL BOX | 10 |
2.2 AIR HANDLING PARTS | 11 |
2.2.1 HEATER ASSEMBLY AND CROSS |
|
FLOW FAN | 11 |
2.2.2 FAN | 11 |
2.2.3 SHROUD | 12 |
2.3 ELECTRICAL PARTS | 12 |
2.3.1 OUTDOOR MOTOR | 12 |
2.3.2 INDOOR MOTOR | 12 |
2.3.3 COMPRESSOR | 12 |
2.3.4 CAPACITOR | 12 |
2.3.5 POWER CORD | 13 |
2.3.6 P.C.B | 13 |
2.4 REFRIGERATION CYCLE | 14 |
2.4.1 CONDENSER | 14 |
2.4.2 EVAPORATOR | 14 |
2.4.3 CAPILLARY TUBE | 14 |
3. INSTALLATION |
|
3.1 HOW TO INSTALL THE UNIT | 17 |
3.2 SUGGESTED TOOL REQUIREMENTS | 18 |
3.2.1 PREPARATION OF SLEEVE | 18 |
3.2.2 PREPARATION OF THE FRONT |
|
GRILLE | 18 |
3.2.3 UNIT INSTALLATION | 19 |
3.3 ELECTRICAL REQUIREMENTS | 20 |
3.3.1 ELECTRICAL DATA (FOR 230V/208 MODEL) | 20 |
3.3.2 ELECTRICAL SAFETY | 20 |
4. FERFORMANCE DATA | 21 |
5. TROUBLESHOOTING GUIDE |
|
5.1 OUTSIDE DIMENSIONS | 26 |
5.2 PIPING SYSTEM | 26 |
5.3 TROUBLESHOOTING GUIDE | 27 |
6. SCHEMATIC DIAGRAM | 32 |
7. EXPLODED VIEW | 33 |
8. REPLACEMENT PARTS LIST | 34 |
1. PREFACE
This SERVICE MANUAL provides various service information, including the mechanical and electrical parts etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
1.When servicing the unit, set the ROTARY SWITCH or POWER SWITCH to OFF(O) and unplug the power cord.
2.Observe the original lead dress.
If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
3.After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.
1.2 INSULATION RESISTANCE TEST
1.Unplug the power cord and connect a jumper between 2 pins (black and white).
2.The grounding conductor (green or green & yellow) is to be open.
3.Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all the positions (except OFF or O) of the ROTARY SWITCH.
4.The value should be over 2MΩ .