—24—
Cooling change of temperature - Air Conditioners
Room Air Room Air LP120CEM
Dry Wet Temperature Across
Bulb Bulb Indoor Coil ( T)
Min Max
Rating Btu/h 11700 12000
Rating CFM 300 330
85 1 5
80 9 13
90 75 18 22
70 26 30
80 5 10
75 13 18
85 70 21 25
65 29 33
75 9 13
70 15 20
80 65 23 26
60 29 33
70 10 15
65 15 20
75 60 21 25
55 26 30
65 9 13
70 60 13 17
55 18 21
Model
Room Air Room Air LP090HEM LP120HEM
Dry Wet Temperature Across Temperature Across
Bulb Bulb Indoor Coil ( T) Indoor Coil ( T)
Min Max Min Max
Rating Btu/h 9300 9600 12300 12600
Rating CFM 240 270 310 340
85 2 6 1 5
80 11 15 10 13
90 75 19 22 18 22
70 29 30 26 30
80 7 11 5 10
75 15 18 14 18
85 70 23 25 21 25
65 31 33 30 33
75 11 15 10 13
70 18 20 16 20
80 65 24 27 23 26
60 32 33 30 33
70 13 16 11 15
65 18 21 16 20
75 60 23 26 21 25
55 29 31 26 30
65 12 15 10 13
70 60 16 18 14 17
55 20 22 18 21
Cooling Change of Temperature - Heat Pumps