(3)Setting C/N on/off ..............................."CO"
Function | Setting and querying C/N set in Step (4) on/off. | ||
Syntax | CO_n | (Setting, reply) | |
| CO_? | (Query) | |
|
|
|
|
n |
| C/N On/Off |
0Off
1On
(4)Setting and querying C/N value.........."CN"
Function | Setting and querying C/N value added. | ||
Syntax | CN_i | (Setting, reply) | |
| CN_? | (Query) |
|
i C/N value: 0 to 31.0 (dB) | Effective down to one digit after the decimal point |
(5)Incrementing C/N value......................"CU"
Function | Incrementing C/N value in current steps. | |
Syntax | CU | (Setting) |
(6)Decrementing C/N value ...................."CD"
Function | Decrementing C/N value in current steps. | |
Syntax | CD | (Setting) |
(7)Setting preset steps for C/N value......"CL"
Function | Setting preset steps for incrementing and decrementing C/N value. | ||
Syntax | CL_n | (Setting, reply) | |
| CL_? | (Query) | |
|
|
| |
n | C/N Value Steps |
00.1
11.0
210.0
(8)Setting BER measurement................."BO"
Function | Setting and querying BER measurement. | ||
Syntax | BO_n | (Setting, reply) | |
| BO_? | (Query) | |
|
|
| |
n | BER Measurement |
0Off
1On
*Only when Source on the TS Source screen is set to PN, this program code is turned on effectively and automatically.