Installer Menu (Cont.)
Detailed Descriptions of Installer Menu Items
000 - INSTALLER SEQUENCE
Specifies entry sequence to the Installer Menu.
0 = 9876 | 1 = 4321 |
2 = 1478 | 3 = 3698 |
001 - POWER MANAGE (Power Management) Determines hours of no activity before automatic shutoff. The Power Management function is for saving energy. If set to 0, Power Management is Off. Settings range from 0 ~ 7, with 1 ~ 7 representing the hours that the unit will remain ON, unless there has been activity from either the control panel or remote control.
002 - AC ON (AC Power Switchable)
If set to 1, this allows the TV to turn ON when AC power is applied. Pressing the POWER button is not necessary. This is desirable if the TV is plugged into a switched AC outlet (i.e., a
Note: If set to 1, the TV does not respond to ON/OFF commands from either the remote or the display panel, and the SLEEP TIMER is also nonfunctional.
003 - BAND/AFC (Band/Automatic Frequency Control) There are four possible settings for this option:
0 | = Broadcast | 1 | = CATV (default) |
2 | = HRC | 3 | = IRC |
If some channels were not found by Auto Tuning (Channel Search), select the appropriate Band setting here, and add the channels using the Channel Edit option in the Channel Menu.
004 - STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial Major Start Channel number when the TV is turned ON. This feature is useful for an
0 | = Aux | 127 | = Map to Major CH 4 |
1 | ~ 125 = Major CH # | 255 | = Last Channel |
126 = Map to Major CH 3 |
|
|
Note: For a digital Start Channel, always remember to set item 104 to the Minor Start Channel number.
Note: 126 and 127 are mapped only in LodgeNet PPV Mode.
005 - CHAN LOCK (Channel Lock)
Channel Lock is ideal if the system must always be on the same channel. Changing channels with the Channel Up/Down or keypad numbers is impossible. Channel Lock is inactive if set to 0 (default).
Generally, this feature is used in connection with item 004 STRT CHANNEL where the Start Channel may, for example, be set to
3 or 4. If the Start Channel is 3, then the TV will remain locked on channel 3.
NOTE: For items 007, 008, and 009
For legacy reasons, the scale used is 0 - 63. The PTC software will translate this to the 0 - 100 scale used by the TV.
To translate a TV volume level to the Installer Menu value, use the following formula:
Installer Value = TV Value x 63 100
Enter only the whole number (disregard fractions).
007 - STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial volume level setting when the TV is turned ON. This feature is useful for an
008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable with the Volume (VOL) Up/Down control. In this way, for example, someone cannot set the volume too low to hear. The value range is from 0 to 63. The factory default is 0, which provides the full range of volume control, if item 009 MAX VOLUME is set to 63. It is recommended to set the same value on every TV.
Note: The minimum volume level cannot have a value setting higher than the maximum volume level (described below).
009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable with the Volume (VOL) Up/Down control. In this way, for example, someone cannot set the volume level high enough to disturb others. The value range is 0 to 63, with 63 as the default, which gives the user the full range of volume control, if item 008 MIN VOLUME is set to 0. It is recommended to set the same value on every TV.
Note: The maximum volume level cannot have a value setting lower than the minimum volume level (described above).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot be muted. If set to 0, sound can be muted.
011 - KEY DEFEAT
If set to 1, Key Defeat is enabled, which means that end users cannot navigate within the
19 |