Installer Menu (Cont.)
012 - IR BANKS EN (IR Banks Enable)
For direct access to a particular channel bank. When enabled, you can access a channel bank by inputting the discrete IR code for that bank.
Note: This item is not available in the Installer Menu when item 027 HOSPITAL MODE is set to 0.
013 - SCAN MODE (Functional after
When set to 1 (default), allows TV to be turned ON when Channel Up/Down buttons are pressed on pillow speaker. Also, TV will turn OFF when Channel Up/Down key is used to tune above or below Channel Map pivot point. By default, Channel Map pivot point is between the highest and lowest channel in the Channel Map (also see item 014 STRT CH IN SM). Set to 0 to disable.
014 - STRT CH IN SM (Start Channel in Scan Mode)
Only valid when item 013 SCAN MODE is set to 1 (enabled). When set to 1, forces Channel Map pivot point to be between the RF channel designated in item 004 STRT CHANNEL and next lower channel in the Channel Map. Set to 0 to disable (default).
Note: This item is not available in the Installer Menu when item 013 SCAN MODE is set to 0.
015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers)
If set to 1, the Timer function is available to the end user and enabled continuously. Set to 0 to disable On/Off timers.
Note: The TV clock must be set in order for timers to be used.
017 - ALARM
Gives the installer the option of making the Alarm function available to the end user. If set to 1, the Alarm function is available to the end user. Set to 0 to disable the Alarm function.
Note: The TV clock must be set before the Alarm function will work.
020 - FEATURE LEVEL
This function determines an additional IR code scheme to which the TV will respond, allowing for the use of unique IR codes based on “bed number” in a
Note: Item 027 HOSPITAL MODE must be set to 0 to enable Legacy Zenith Bed 1 or Bed 2 IR codes and Speaker selections.
Values | IR Mode | Bed # | Speaker |
Legacy Zenith (Hospital) | TV | ||
TV | |||
Legacy Zenith (Hospital) | Pillow |
Note: For further information, see documentation for the accessory package that includes the
021 -
Set to 1 to activate
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum
Note: This item is not available in the Installer Menu when item 084 PERMANENT BLK is set to 1.
023 - CAPTION LOCK
If set to 0, captions are OFF when the TV is turned ON. Set to 1 to use the caption setting configured before the TV was turned OFF when the TV is turned ON.
025 - FUNCTION PRE (Function Preview)
Set to 1 to allow access to the Channel Preview/Banks Setup Menu via the CH PREVIEW key on Installer Remote. Set to 0 to disable access to the Channel Preview/Banks Setup Menu.
027 - HOSPITAL MODE
Set according to the speaker selection, the pillow speaker code/ supply voltage and the hospital IR code. If using a Pro:Centric pillow speaker, select one of the Zenith codes in accordance with the desired speaker selection. See table below.
Value | Speaker | Pillow Speaker | Hospital IR Code | |
Code/Voltage | ||||
|
|
| ||
000 | Determined by | Zenith (+12v) | Determined by item | |
| item 020 setting |
| 020 setting | |
001 | Pillow Only | Zenith (+12v) | Zenith Bed #1 | |
002 | Pillow Only | Zenith (+12v) | Zenith Bed #2 | |
017 | Pillow Only | Philips (+5v) | Zenith Bed #1 | |
018 | Pillow Only | Philips (+5v) | Zenith Bed #2 | |
033 | Pillow Only | RCA | Zenith Bed #1 | |
034 | Pillow Only | RCA | Zenith Bed #2 | |
065 | TV Only | Zenith (+12v) | Zenith Bed #1 | |
066 | TV Only | Zenith (+12v) | Zenith Bed #2 | |
081 | TV Only | Philips (+5v) | Zenith Bed #1 | |
082 | TV Only | Philips (+5v) | Zenith Bed #2 | |
097 | TV Only | RCA | Zenith Bed #1 | |
098 | TV Only | RCA | Zenith Bed #2 | |
129 | Both Pillow & TV | Zenith (+12v) | Zenith Bed #1 | |
130 | Both Pillow & TV | Zenith (+12v) | Zenith Bed #2 | |
145 | Both Pillow & TV | Philips (+5v) | Zenith Bed #1 | |
146 | Both Pillow & TV | Philips (+5v) | Zenith Bed #2 | |
161 | Both Pillow & TV | RCA | Zenith Bed #1 | |
162 | Both Pillow & TV | RCA | Zenith Bed #2 | |
254 | TV Only | Disabled (0v) | Zenith Bed #2 |