LG Electronics D2102W Four-Wire Connection for Electric Dryers Direct Wire, wWARNING, Usa Only

Models: 3828EL3004T

1 112
Download 112 pages 44.13 Kb
Page 19
Image 19
Four-Wire Connection for Electric Dryers: Direct Wire

•Use UL-listed4-wire #10 AWG-minimum copper conductor cable. CONNECTING ELECTRIC DRYERS (cont.)

USA ONLY

wWARNING:

Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-Wire Connection for Electric Dryers: Direct Wire

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1" (2.5 cm)

Ground Wire

5"

(12.7 cm)

Use UL-listed4-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft (1.5 m) length to allow for removal and reinstallation of the dryer.

Terminal

Manual background Block

UL-Listed

Manual background Strain Relief

UL-Listed 4-Wire Power Cord

1Remove 5 inches (12.7 cm) of the outer covering from the wire. Remove 5 inches of insulation from the ground wire. Cut off approximately 112 inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.

2Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Hot

Neutral

Hot

(Black)

(White)

(Red)

Ground Screw Manual backgroundManual backgroundManual background

Ground Wire

3 Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.

19 Manual background

Page 19
Image 19
LG Electronics D2102W Four-Wire Connection for Electric Dryers Direct Wire, wWARNING, CONNECTING ELECTRIC DRYERS cont