12. Alarm mode display / only displayed while operating.

CO : The sensor for sensing room temperature is open or short.

C1 : The sensor for sensing piping temperature is open or short.

13.Energy Saving

If setting temperature of starting energy saving operation is under 22°C(71.6°F), first, setting temperature it up to 22°C(71.6°F) and perform energy saving operation.

After energy saving operation starts, if adaptation time of the human body pass from the point which room temperature and setting temperature meet together, increase setting temperature 1°C(1.8°F) more.

If it doesn't satisfy number even in 50 minutes from the start of energy saving operation, increase 1°C(1.8°F).

After increasing setting temperature 1°C(1.8°F) more by number , , perform number , again, if setting temperature goes up to 25°C(77.0°F), maintain this temperature.

If setting temperature goes down to under 25°C(77.0°F), during the operation, do number , , again.

27°C(80.6°F)

 

 

 

 

 

26°C(78.8°F)

 

 

 

 

 

25˚C(77.0°F)

 

 

 

 

 

24°C(75.2°F)

 

 

 

 

 

23°C(73.4°F)

 

 

 

 

 

22°C(71.6°F)

 

 

 

 

 

21°C(69.8°F)

 

 

 

 

 

28min.

35min.

47min.

 

50min.

50min.

50min.

 

Setting energy

Setting temp.

Setting temp.

Setting temp.

maintains setting temp.

saving operation

23°C(73.4°F)

24°C(75.2°F)

25°C(77.0°F)

25°C(77.0°F)

14. AUTO RESTART

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

15. Function of changing set temperature when re-operation after stop.

Operation is set the following condition when re-operation with start/stop button.

1.Operation mode.

Cooling/soft dry mode Cooling mode Heating mode Heating mode

2.Setting the set temperature when cooling operation.

Room temperature > Set temperature: to be set to the previous set temperature. Room temperature Set temperature

a)Room temperature 26°C(78.8°F): to be set to 24°C(75.2°F)

b)22°C(71.6°F) Room temperature 25°C(77.0°F): to be set to 21°C(69.8°F)

c)19°C(66.2°F) Room temperature 21°C(69.8°F): to be set to -1°C(1.8°F) less than room temperature.

d)Room temperature 18°C(64.4°F): to be set to 18°C(64.4°F)