The unit is working, but not cooling and heating sufficiently

(Both blower and compressor are working)

 

 

 

 

 

 

 

WHAT TROUBLED

COMPLAINTS

HOW TO CHECK

REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

Load

Much heat load

Heat load increased.

Do necessary disposal

 

 

 

Window or door has many

respectively.

 

 

 

cracks or gaps.

 

 

 

 

 

 

 

 

Air flow

Obstacle disturbs Intake

Checking

Correct it.

 

 

of uniform wind.

 

 

 

 

 

 

 

 

 

Short air volume

Reverse rotation of

Checking

Correct it.

 

 

blower.

 

 

 

 

 

 

 

 

 

Refrigerant

Shortage in the charged

Coil inlet pipe is frosted

Replenish it.

 

 

refrigerant.

 

(Repair the leakage spot).

 

 

 

 

 

 

Air passage

Improper or foreign bodies

Checking

Correct or clear the

 

 

 

 

foreign bodies.

 

 

 

 

 

 

Air filter

Clogged with dust

Checking

Cleaning

 

 

 

 

 

 

9.4 All the functions are performed normally, but very noisily and much vibratively.

 

 

 

 

 

 

 

WHAT TROUBLED

COMPLAINTS

HOW TO CHECK

REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

Liquid refrigerant flooding

• Check for refrigerant over-charge.

 

 

back from the evaporator.

• Check to see if the intaking air temperature is

 

 

 

extremely cold.

 

 

 

 

 

• Check for insufficient air flow quantity.

 

 

 

 

 

 

 

Compressor shipping

• Checking

• Remove the shipping

 

 

bracket is not removed.

 

bracket.

 

 

 

 

 

 

 

Faulty discharge valve and

• Checking

• Replace the

 

 

suction valve.

 

compressor

 

 

 

 

 

 

Blower

Fan broken.

Checking

• Repair or replace it.

 

 

Other materials intruded.

 

• Clear the other

 

 

 

material

 

 

 

 

 

 

 

 

 

 

Screws

Looseness or fail-off of

Checking

Repair

 

 

screws

 

 

 

 

 

 

 

 

 

–31–

Page 31
Image 31
LG Electronics LF300CP(LP-C303R20), LF480CE(LP-C483TA0) Unit is working, but not cooling and heating sufficiently