Base Station Cabling
The Base Station is connected to the WTI(wireless terminal interface) ports of
The cable for connecting the KSU with a base station should be a twisted pair cable.
The cable for connecting the KSU with a base station shall be separately cabled. This connection shall be cabled separate to the building cabling using one pair CAT5 cabling.
Twisted pair shielded cables should be used with all outdoor configurations. The following characteristics should be observed for all cables:
DC resistance: The resistance of a conductor should not exceed 73.4 ohm per km for a temperature of 20 degree.
Attenuation: The attenuation of any pair should not exceed 17 dB per km on condition of a temperature of 20 degree and frequency of 1 MHz.
Characteristic impedance: Characteristic impedance should remain in the range of 100 ohm _ 15% for a frequency of 1 MHz.
Crosstalk: The total crosstalk of any pair
The maximum connection length depends upon cable size(φ). [Table 3.6.4] shows the resistance and the maximum cable length.
Cable Type | Resistance | Maximum Cable Length |
0.4 mm cable (Awg26) | 0.27 Ω/m | 150m |
0.5 mm cable (Awg24) | 0.18 Ω/m | 300m |
0.6 mm cable (Awg22) | 0.11 Ω/m | 450m |
[Table 3.6.4] Cable Resistance and Maximum Cable Length