GDK-20W DIGITAL WIRELESS KEY TELEPHONE SYSTEM

3.4 PCB INSTALLATION

PCB Handling & General Installation

All boards should not be installed or removed while power applied.

Power must be turned off prior to insertion or removal of the PCB.

The system PCBs contain digital circuitry which can be damaged by exposure to excessive static electricity. When handling PCBs, a grounded wrist strap should be used to protect the boards from static discharges. Also, use common sense when handling the PCBs. For example, do not place a PCB in locations where heavy objects might fall on the PCB and damage components.

To insert a PCB, hold the PCB and, with component side facing right, insert the card into the MBU’s din connector firmly and tighten. To remove a PCB, reverse the procedure. Installation method of PCB is shown in Figure 3.4.1.

Figure 3.4.1 PCB Installation

There are 6 slots in the GDK-20W system for extend or modify the system configuration. But, there are some restrictions when optional board installation. Note that the system can not operate properly with wrong installation. The SLOT1 of the MBU is reserved only for DVIB/DVIBE, the SLOT2 & SLOT3 is reserved for LCOBs or STIB2/STIB, the SLOT4 are reserved only for PMU and the SLOT5 and SLOT6 is reserved for WTIB and MFB, respectively.

To summarize, see the following table 3.4.1.

Slot No.

Cards

Remark

 

 

 

SLOT1

DVIB, DVIBE

Fixed slot for DVIB

SLOT2

LCOB2, LCOB, LCOBE,

Option board for LCO, ISDN

SLOT3

LCOBA, LCOB4,STIB2, STIB

 

SLOT4

PMU

Fixed slot for PMU(Basic)

SLOT5

WTIB

Fixed slot for WTIB

SLOT6

MFB

Fixed slot for MFB

[Table 3.4.1] Option Boards Installation Table

When the system power on, the default slot assignment is automatically redefined according to board installation status.

Main Board Unit (MBU) Installation

The MBU is installed in the KSU default. It comprised of main processor, four(4) Digital Terminal interface circuits, two(2)