For 16 mm -thick unit walls

Putting into operation

u Fit the equaliser trim Fig. 10 (20) concentri- cally onto the appliance: Slide it into the recess and engage it in the keyholes.

Fig. 10

u Screw all the mounting brackets Fig. 11 (34) to the pre-drilled holes in the appliance door using hexagon screws Fig. 11 (35).

Fig. 11

For 16 mm -thick unit walls

 

 

= 568 mm-wide recess:

 

 

 

 

u Clip spacer Fig. 12 (23) onto

 

 

 

the upper hinge and spacer

 

 

 

Fig. 8 (24) onto the lower

 

 

 

hinge.

 

 

 

 

 

Fig. 12

u Attach

the

top cover

 

 

 

 

 

Fig. 13 (53) and bottom

 

 

 

cover Fig. 13 (50) to the

 

 

 

mounting brackets.

 

 

 

 

u Fasten

the

mounting

 

 

 

brackets Fig. 13 (50) at the

 

 

 

top and bottom with screws

 

 

 

Fig. 13 (51) so that the

 

 

 

brackets can still be moved

 

 

 

a little to the left and right.

 

 

Fig. 13

u Strip the protective film off the cover trim

 

Fig. 14

(22).

Apply

the

cover

trim

 

Fig. 14 (22) to the projection of the cover

 

Fig. 13 (53) on the handle side, flush with

 

the front, and adhesively affix it to the side

 

wall of the appliance.

the

cover

strip

 

u If necessary,

shorten

Fig. 14

Fig. 14 (22) at the bottom: The cover strip

Fig. 14 (22) has to end 3 mm above the

 

upper edge of the lower mounting bracket

 

Fig. 8 (50).

 

 

 

 

 

Slide in and align the appliance:

u Slide in the appliance until the covers Fig. 13 (53)abut Fig. 13 against the side wall of the kitchen unit.

u Extend the adjustable foot.

For 16 mm-thick unit walls = 568 mm-wide recess:

u Allow the spacers to abut against the side wall of the kitchen unit.

Fig. 15

For 19 mm-thick unit walls =

562 mm-wide recess:

u Align the front edges of the hinges so as to be flush with the side wall of the kitchen unit.

Fig. 16

For kitchen units (16 mm and 19 mm ) with door stop components (knobs, sealing lips etc.):

u Allow for the extra distance (depth of the door stop compo- nents): Allow hinges and covers Fig. 13 (53) to protrude by the extra distance.

All appliances:

u Vertically align the appliance by means of the adjustable- height feet Fig. 8 (25), using the accompanying open-ended spanner Fig. 8 (26).

w The appliance is now correctly positioned in depth. The distance from the front edge of the side wall of the unit to the appliance body is 42 mm all the way round. (Allow for door stop components, such as knobs and sealing lips.)

Note

Incorrect installation will lead to malfunction!

If the distance is not kept, the door may not close. This may lead to icing, to condensate forming and to malfunction.

u Be sure to keep to the clearance of 42 mm all the way round. (Allow for door stop components, such as knobs and sealing lips.)

Tightly screw the appliance into place in the recess:

u At the top and bottom

 

of both doors

with

 

Spax

 

screws

 

Fig. 17

(28) passed

 

through

the

hinge

 

plates.

 

 

 

 

 

On the handle side at the top:

Fig. 17

 

u Loosen

the

screws

 

Fig. 18 (51) a little.

 

 

u Tightly

screw

the top

 

mounting

 

bracket

 

Fig. 18 (50) to the unit

 

wall

using

Spax

screw

 

Fig. 18 (29) ø4x19.

 

 

u Break off the projecting

 

end

of

the

 

cover

Fig. 18

Fig. 18 (53).

 

 

u Tighten the screws Fig. 18 (51).

 

u Put on the cover Fig. 18 (53).

 

On the handle side at the bottom:

 

u Loosen

 

the

 

screws

 

Fig. 19 (51) a little.

 

 

u Tightly screw the bottom

 

mounting

 

bracket

 

Fig. 19 (50) to the unit

 

wall

using

Spax

screw

 

Fig. 19 (29) ø4x19.

 

 

u Break off the projecting

 

end

 

of

the

cover

 

Fig. 19 (53). It is no longer

 

required.

the

 

screws

 

u Tighten

 

 

 

Fig. 19 (51).

 

 

Fig. 19

u Put the cover Fig. 19 (54)

on

the

bottom

mounting

 

bracket Fig. 19 (50).

 

u Close the appliance door.

 

4.5.2 Fitting the unit doors

Fig. 13 (53) and bottom Fig. 20

8

Page 8
Image 8
Liebherr 7084284-03 Fitting the unit doors, For 16 mm -thick unit walls, 53 and bottom, cover 50 to the, 51 so that the