TROUBLESHOOTING AND REPAIR

F-14

 

 

 

 

 

 

 

 

 

 

 

 

MAIN TRANSFORMER TEST (continued)

 

 

 

 

TABLE F.1 – TEST POINTS

 

 

 

 

 

 

 

 

 

INPUT VOLTAGE

TEST POINTS

EXPECTED VOLTAGE READING

 

 

 

 

 

 

 

 

230 VAC

X1-X2

 

11.9-13.0 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X3

 

14.1-15.2 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X4

 

16.2-17.5 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X5

 

18.4-19.7 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X6

 

20.5-22.0 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X7

 

22.7-24.2 VAC

 

 

 

 

 

 

 

 

230 VAC

X1-X8

 

24.8-26.5 VAC

 

 

 

 

 

 

 

 

230 VAC

X9-X10

 

26.9-28.8 VAC

 

 

 

 

 

 

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

12.If ALL the voltages tested are incorrect or miss- ing, test for correct nameplate input voltage between the H1 lead at the ON/OFF POWER SWITCH to H2 or H3 at the reconnect panel. Voltage tested will vary depending on input voltage connection. See Wiring Diagram for test point locations.

A.If the input voltage test is incorrect, check for loose or broken leads between the reconnect panel and the ON/OFF POWER SWITCH.

B.Test the ON/OFF POWER SWITCH for proper operation.

13.If the correct nameplate voltage is being applied to the main transformer and one or more of the secondary voltages are missing or are incorrect, the main transformer may be faulty. Replace.

14.When test is complete, replace tool tray, case sides and top.