MAINTENANCE | ||
|
|
|
6.Remove the two trigger terminals from the modular trigger terminal housing.
7.Remove the incoming connector assembly (see Item 8 Figure A.4, Installation Section) from the gun cable.
8.Remove the damaged gun cable by sliding it rear- ward from the vacuum hose.
9.Install the new gun cable by sliding it forward through the vacuum hose.
10.Reassemble gun by reversing steps 1 through 7, noting the following:
•Route trigger leads per this section Trigger and Accessory Switch Lead Routings (see figure D.1).
•Installation torques for both the incoming connector and gun tube assemblies: 10 to 12
•The order of connection of the trigger termi- nals (red and white leads) to the trigger assembly or in the Y connector is unimpor- tant
•Reassemble the Y connector by reversing steps shown in 5.
•Install a new liner if it does not meet the cut dimensional range given per this section Liner Assembly Cleaning or Replacement.