D-4

MAINTENANCE

D-4

 

 

 

6.Remove the two trigger terminals from the modular trigger terminal housing.

7.Remove the incoming connector assembly (see Item 8 Figure A.4, Installation Section) from the gun cable.

8.Remove the damaged gun cable by sliding it rear- ward from the vacuum hose.

9.Install the new gun cable by sliding it forward through the vacuum hose.

10.Reassemble gun by reversing steps 1 through 7, noting the following:

Route trigger leads per this section Trigger and Accessory Switch Lead Routings (see figure D.1).

Installation torques for both the incoming connector and gun tube assemblies: 10 to 12 ft.-lbs..

The order of connection of the trigger termi- nals (red and white leads) to the trigger assembly or in the Y connector is unimpor- tant (non-polarized connections).

Reassemble the Y connector by reversing steps shown in 5.

Install a new liner if it does not meet the cut dimensional range given per this section Liner Assembly Cleaning or Replacement.

MAGNUM™ PRO 350 and 550 FUME GUNS

Page 21
Image 21
Lincoln Electric 550, 350 manual Maintenance