Lincoln Electric 550, 350 Trigger and Accessory Switch Lead Routings, Gun Handle, See Figure D.1

Models: 550 350

1 31
Download 31 pages 44.49 Kb
Page 19
Image 19

D-2

MAINTENANCE

D-2

 

 

 

TRIGGER AND ACCESSORY SWITCH LEAD ROUTINGS

(Gun Handle, See Figure D.1)

Route the trigger (red and white) and accessory (blue and black) leads following the steps shown below. Proper routing:

Provides adequate slack so that the handle can rotate to its trigger-up or trigger-down positions without damaging or disconnecting the leads.

Avoids fume air flow blockage and unnecessary restrictions through the handle.

1.Start with trigger and gun tube in the trigger-down position (See Figure B.1, Operation Section). Run sleeved accessory switch leads (blue and black) parallel to gun centerline. Rear end of sleev- ing (right-side in photo) is even with copper cable nut end.

2.Run sleeved trigger leads (red and white) parallel to gun centerline and next to accessory leads sleeving. Rear end of sleeving (right-side in photo) is even with copper cable nut end.

3.Remove slack in both pairs of control leads here.

4.Secure both sleeved groups to the copper cable cone with a cable tie. Do not attach any unsleeved leads here.

5.Route trigger leads in a loop over and then under- neath the gun tube.

6.Trigger leads emerge from under the gun tube, pass thru lead slot in gun handle, and then connect to the trigger. Either lead may be connected to either trigger pin (non-polarized connections).

7.Route accessory leads under and then over the gun tube. Secure free ends of both leads to the gun tube with a cable tie. When reassembling the gun, be careful not to pinch any leads between gun handle halves.

FIGURE D.1

MAGNUM™ PRO 350 and 550 FUME GUNS

Page 19
Image 19
Lincoln Electric 550, 350 manual Trigger and Accessory Switch Lead Routings, Gun Handle, See Figure D.1