E-2

 

TROUBLESHOOTING

 

E-2

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE

 

RECOMMENDED

 

 

(SYMPTOMS)

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

PROBLEMS

 

 

 

No wire feed occurs when trigger is

1.

Machine is switched off or unplugged.

1.

Switch on or plug in machine.

 

pulled

2.

Out of wire.

2.

Install full spool of specified wire.

 

 

 

 

 

 

3.

Contact tip burnback.

3.

Replace contact tip.

 

 

 

4.

Fully or partially blocked gun liner

4.

Remove and clean or replace gun

 

 

 

 

 

 

liner, (See Maintenance Section).

 

 

 

5.

Bird nest.

5.

Cut out bird nest, reload wire, and

 

 

 

 

 

 

check for proper wire alignment.

 

 

 

6.

Defective trigger (contacts open or

6.

Replace trigger (See Maintenance

 

 

 

 

dirty).

 

Section)

 

 

 

7.

Defective trigger circuit in gun.

7.

Disconnect gun from machine and

 

 

 

 

 

 

check trigger circuit for continuity.

 

 

 

8.

No motor voltage or current from

8.

See Troubleshooting section in weld-

 

 

 

 

machine.

 

ing machineʼs or wire feederʼs instruc-

 

 

 

 

 

 

tion manual.

 

 

 

9.

Contact tip size too small for wire

9.

Replace contact tip with one that is the

 

 

 

 

diameter used.

 

correct size.

 

Sluggish wire feed when trigger is pulled

1.

Drive roll is worn or galled.

1.

Clean drive roll or replace drive roll.

 

 

 

2.

Machineʼs wire feed speed setting is

2.

Increase wire feed speed.

 

 

 

 

too low.

 

 

 

 

 

3.

Wire is obstructed somewhere along

3.

Check for obstructions: remove any

 

 

 

 

the wire feed path in the gun.

 

wire shavings; remove kinked wire;

 

 

 

 

 

 

remove and clean or replace gun tube

 

 

 

 

 

 

liner (See Maintenance Section ).

 

 

 

4.

Low motor voltage.

4.

See Troubleshooting section in weld-

 

 

 

 

 

 

ing machineʼs instruction manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.