Connection of the LN-7 to the Ranger 8

OPERATING

a. Shut the welder off.

INSTRUCTIONS

 

b. Connect the LN-7 and the K240 contactor kit per

Additional Safety Precautions

 

instructions on the connection diagram S17742

Always operate the welder with the roof and case

(can be found in the back of this manual).

sides in place as this provides maximum protection

 

c. Place the “RANGE” switch to the “WIRE FEED”

from moving parts and assures proper cooling air flow.

 

position and the “POLARITY” switch to the

Do not tamper with the carburetor settings or the fuel

desired polarity.

hose from the regulator to the carburetor. The engine

 

d. Place the “IDLER” switch in the “HIGH” idle

has been pre-set for optimum performance. Changes

in the carburetor settings or fuel hose length can

position. The engine idling device may not

result in reduced performance and excessive carbon

function when welding in the “WIRE FEED” mode.

monoxide emmisions.

 

e. Adjust wire feed speed at the LN-7 and adjust the

Read and understand all Safety Precautions before

welding voltage with the output “CONTROL” at

operating this machine. Always follow these and any

the welder.

other safety procedures included in this manual and in

NOTE: If the output “CONTROL” is set below “3” the

the Engine Owner’s Manual.

K240 contactor may not pull in.

 

Connection of TIG Module (K930-1) to the Ranger 8

The TIG Module is an accessory that provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding. See IM528 supplied with the TIG Module for installation instructions.

Note: The TIG Module does not require the use of a high frequency bypass capacitor. If any other high frequency accessory is used with the Ranger 8, a bypass capacitor (Order Kit T12246) must be installed in the Ranger 8.

Welder Operation

Welder Output

Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS.

Duty Cycle: 100% for both welding and auxiliary power.

Ranger 8 LPG

Constant Current

225 Amps AC @ 25 Volts

 

 

210 Amps DC @ 25 Volts

 

 

 

Constant Voltage

200 Amps DC @ 20 Volts

 

 

 

Ranger 8 LPG Typical Fuel Consumption

 

KOHLER CH20S

 

COMMAND®

 

 

Low Idle - No Load

1.60 lb/Hour

(0.73 kg/Hour)

 

High Idle - No Load

2.40 lb/Hour

(1.09 kg/Hour)

 

 

 

 

1/2 Load

5.40 lb/Hour

(2.45 kg/Hour)

 

 

 

3/4 Load

7.00 lb/Hour

(3.18 kg/Hour)

 

 

 

Full Load

8.50 lb/Hour

(3.86 kg/Hour)

 

 

 

 