C-2

ACCESSORIES

C-2

MIG (GMAW)

CONVERSION

Several changes are needed to convert the unit for operation with the MIG (GMAW) process. The follow- ing conversions should be reviewed before welding with (GMAW):

1.Change the output polarity to DC(+). See Work Cable Installationin Installation section for details.

2.Install proper drive roll for the wire size selected. See Changing Drive Rollin Maintenance section for details.

3.Install the proper gun liner and tip for the wire size selected. See Component Replacementin Maintenance section for details.

4.Remove gasless nozzle (if installed) and install gas nozzle.

5.Load wire into machine and thread into gun and cable per Welding Wire Loadingsection.

REPLACEMENT PARTS

Complete Gun and Cable Assembly (Code 10983)

L11951

Complete Gun and Cable Assembly (Code 10982)

L8311-5