E-4

TROubLEShOOTING

E-4

 

 

 

 

ELECTRONIC IDLER TROubLEShOOTING GuIDE

 

With Idler Control Switch in the AuTO Position,

Engine Will Not Pick up Speed When:

The Arc is Struck

Reed Switch in Weld Circuit

Defective -- Will Not Close

To Check: Short the Red Lead on P.C. Board to Welder Frame.

The Auxiliary Power Load is Turned ON

Power Load Too Small

Try Load Above 150 Watts

Engine Does Not Pick up Speed

Engine Picks up Speed

Engine Does Not Pick up

 

 

Speed

1. Check for Break in

 

 

Red Lead and Repair

1.

Check for Jamming of

 

 

the Idler Solenoid

2. Replace Reed Switch

 

Mechanism, or broken

in Weld Circuit.

 

return spring.

 

2.

Check Idler Circuit

 

 

Wiring and Repair as

 

 

Required.

 

3.

Replace Idler P.C.

 

 

Board.

1.Check for Jamming of the Idler Solenoid Mechanism, or broken return spring.

2.Check for Continuity of Current Transformer (Toroid). Replace as Required.

3.Check Idler Circuit Wiring and Repair as Required.

4.Replace Idler P.C. Board.

CAuTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SAE-300®

Page 26
Image 26
Lincoln Electric SAE-300 manual Defective -- Will Not Close, Auxiliary Power Load is Turned on