TROubLEShOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PRObLEMS
(SYMPTOMS)
POSSIbLE
CAuSE
RECOMMENDED
COuRSE OF ACTION
White or Blue Smoke. | 1. | Excess engine oil. |
|
|
| 2. | Too low viscosity of the engine |
| |
|
| oil. |
|
|
| 3. | Faulty injection timing. |
|
|
|
|
|
|
|
Dark Grey Smoke. | 1. | Unsuitable fuel. |
|
|
| 2. | Excess injection. |
|
|
| 3. | Faulty function of the engine. |
| |
| 4. | Overloading. |
|
|
| 5. | Clogged air cleaner. |
|
|
Faulty Charging. | 1. | Loose fan belt. |
|
|
| 2. | Faulty wiring. |
|
|
| 3. | Faulty battery. |
|
|
| 4. | Worn out alternator brush. |
| |
|
|
|
| |
Starter Motor does not run. | 1. | Loose or damaged wiring. |
| |
| 2. | Drained voltage from battery. |
| |
| 3. | Damaged starter | motor |
|
|
| (including solenoid). |
| If all recommended possible areas |
|
|
|
| of misadjustment have been |
|
|
|
| checked and the problem persists, |
Engine Protection Light not com- | 1. | Broken Light Bulb. |
| Contact your local Lincoln |
ing on. | 2. | Faulty light wiring. |
| Authorized Field Service Facility. |
| 3. | Faulty Engine Control Unit. |
| |
|
|
|
|
|
No Auxiliary Power | 1. | Open circuit breakers. |
|
|
|
| Reset breaakers. |
|
|
| 2. | GFCI may have tripped. |
|
|
|
| Follow “GFCI Testing and |
| |
|
| Resetting Procedure” in the |
| |
|
| Maintenace Section of this |
| |
|
| Manual. |
|
|
| 3. | Faulty connections to auxiliary |
| |
|
| receptacles. |
|
|
|
| Check connections |
|
|
|
|
|
|
|
|
|
|
|
|
CAuTION