F-29

F-29

TROUBLESHOOTING & REPAIR

ACTIVE SCR TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot- ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).

DESCRIPTION

The Active SCR Test will determine if the device is able to be gated “ON” and conduct current from anode to cathode.

MATERIALS NEEDED

An SCR tester as outlined in this procedure TIG 275 Wiring Diagram

3/8” Nut driver

This procedure takes approximately 20 minutes to perform.

SQUARE WAVE TIG 275