TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

AC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

0 V

50 V

2 ms

This is the typical AC output voltage waveform generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 2 milliseconds in time.

NOTE: Scope probes connected at

machine output terminals: (+) probe to electrode, (–) probe to work.

NOTE: AC balance control set at “Balanced” position.

SCOPE SETTINGS

Volts/Div

50 V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 

SQUARE WAVE TIG 275