TROUBLESHOOTING & REPAIR

STATIC SCR TEST (continued)

FIGURE F.4 – PLUG J1 LOCATION ON CONTROL BOARD

S-W TIG 275 CONTROL

J1

J8

G3360-[ ]

TEST PROCEDURE

1.Remove main supply power to the TIG 275 and remove the case top and left side.

2.Locate and remove plug J1 from the control board. See Figure F.4.