TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
DC TIG MODE
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
•Perform all voltage and waveform checks with high frequency circuit OFF.
•Perform High Frequency Disable Procedure.
0 V
50 V | 2 ms |
This is the typical DC (+) output volt- age waveform generated from a prop- erly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 2 milliseconds in time.
NOTE: Scope probes connected at
machine output terminals: (+) probe to electrode,
SCOPE SETTINGS
Volts/Div | 50 V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|