E-4

TROUBLESHOOTING

E-4

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

ELECTRICAL FAILURES

 

Machine fails to come on

1.

No Input Voltage.

 

 

(Power LED off)

 

 

 

 

 

2.

Faulty supply plug or cable.

 

 

 

3. Internal fuse blown.

 

 

 

 

 

 

 

Power Input incorrect

1.

Input voltage out of range (less

 

 

Input over-current

 

than 95 or greater than 265VAC).

 

 

(Power LED Flashing)

 

 

 

 

 

2.

Input current too high due to oper-

 

 

 

 

ating beyond rated duty cycle.

 

 

 

 

 

 

 

No output current

1.

While in TIG mode, Trigger circuit

 

 

(Power LED on)

 

not mode at 6 pin amphenol.

 

 

(Output LED off)

 

 

 

 

 

 

 

 

 

Thermal overload

1.

Unit has been operated beyond its

 

 

(Thermal LED on)

 

capacity rating.

 

 

 

2. Airflow through machine is

 

 

 

 

restricted or fan has failed.

 

 

 

 

 

 

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.