Troubleshooting

User Manual

English

Troubleshooting

There are no LED’s illuminated on the Remote Receiver unit

ƒEnsure that the AC Adapter is plugged into the mains and the jack is plugged into the socket on the Remote Receiver.

ƒVerify that the connected PC is switched on. Otherwise it may result in display problems.

There is no video signal displayed on the monitor

ƒCheck that the VGA cables and CAT5 cable are properly connected to the respective ports on the Receiver and Transmitter units.

ƒEnsure the VGA cables are correctly connected to the computers

ƒMake sure the power adapter is connected to the Receiver

ƒIf you still can’t see a picture, try connecting with a short CAT5 patch cable to make sure there is not a fault with the CAT5 cable.

The display is ‘foggy’ or unclear.

ƒCheck that the VGA cables are properly connected.

ƒTry adjusting the VGA Tuning control as described in section Installation

ƒEnsure that the VGA resolution is not set too high for the length of Ethernet cable that is used.

ƒTry a higher specification or shorter length CAT5, 5e or 6 cable

ƒTry reducing the display resolution.