Installation and Service Manual
Figure 39 - Control Panel Component Location Drawing
TABLE-M
Remote Wire Connection
Wire | Maximum |
Gauge | Allowable Length |
12 GA | 100 ft |
14 GA | 75 ft |
16 GA | 50 ft |
18 GA | 30 ft |
|
|
Terminal Strip Connection Options
The scenarios shown in Figures 40 A - C represent typical terminal strip connection requirements. The terminal strips are located on the left side of the pool heater under the electrical access panel. Other applications may be accommodated, but must be addressed individually.
Figure
Figure
also an external pool temperature control, adjust the pool heater’s pool return set point a few degrees higher than the external pool temperature control’s set point. The pool heater temperature control will then act as a backup to the external pool temperature control.