Lochinvar GAS HEATER FOR COMMERICAL POOL APPLICATIONS service manual TABLE-Q AMP Draw Data, Test

Models: GAS HEATER FOR COMMERICAL POOL APPLICATIONS

1 60
Download 60 pages 21.1 Kb
Page 45
Image 45
TABLE-P

Installation and Service Manual

TABLE-P

Recommended Water Chemistry

Test

Recommended Level

 

 

Correct pH

7.2 - 7.8

Chlorine Residual

1.0 - 5.0 PPM

Total Alkalinity

80 - 120 PPM

Calcium Hardness

175 - 350 PPM

 

 

Chlorine residual is the chlorine remaining in the pool water after it is consumed in the process of destroying bacteria, algae and other oxidizable materials. Total alkalinity is the measurement of the total amount of alkaline chemicals in the water. Alkalinity controls pH. Sodium bicarbonate is used to raise total alkalinity. Calcium hardness can be raised by the addition of calcium chloride, and lowered by the addition of Tri-sodium Phosphate or its equivalent. The corrosive level of pool water can also be measured by the Ryznar Stability Index. This index is calculated by a formula which uses operating temperatures, total alkalinity, pH, calcium hardness and total dissolved solids. The Ryznar Stability Index is able to predict more accurately the scaling or corrosive tendencies of swimming pool water. Balanced water within the guidelines of the Ryznar Stability Index are from 6.3 - 6.7. Use of the Ryznar Stability Index may help prolong the service life of pool equipment, which in turn will be a cost savings to the commercial pool owner. Your pool dealer can provide additional data and equipment to make this measurement if a problem exists.

Refer to Circulating Pump on page 46 for information relating to pump wiring.

TABLE-Q

AMP Draw Data

Btu/Hr

 

 

 

Approximate

Input

Controls

Fans

Pump

Total Amps

500,000

3.6

2.7

5.0

11.3

650,000

5.4

3.4

5.0

13.8

 

 

 

 

 

750,000

5.4

3.4

5.0

13.8

 

 

 

 

 

990,000

7.3

3.2

7.4

17.9

 

 

 

 

 

1,260,000

7.3

3.2

7.4

17.9

 

 

 

 

 

1,440,000

7.3

6.7

7.4

21.4

 

 

 

 

 

1,800,000

7.3

6.7

8.8

22.8

2,070,000

7.3

6.7

8.8

22.8

 

 

 

 

 

45

Page 45
Image 45
Lochinvar GAS HEATER FOR COMMERICAL POOL APPLICATIONS TABLE-Q AMP Draw Data, TABLE-P Recommended Water Chemistry, Test