ROUGH-IN INSTRUCTIONS

USING ADJACENT STUD SPACE FOR ALL COMBUSTION AIR FROM OUTSIDE

HOLES CONNECTING TO

VENTILATED ATTIC

CEILING

PLATE

AIR

GRILLE

FLOOR

PLATE

HOLES CONNECTING TO VENTILATED

CRAWL SPACE

BASED ON 4,000 BTU OF TOTAL INPUT RATING OF ALL GAS APPLIANCES, THE HEATER ONLY REQUIRES A MINIMUM FREE AREA OF:

 

SQUARE

HOLE

SQUARE

BTU

IN.

 

SIZE =

 

IN.

 

25,000

6.25

1”

.785

 

35,000

8.75

1.5”

1.76

 

50,000

12.50

2”

3.14

 

55,000

13.75

2.5”

4.90

 

65,000

16.25

3”

7.065

 

ROUGH-IN INSTRUCTIONS

In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper operation.

Minimum clearance from cabinet to combustible

construction:

 

 

Side Wall

-

4”

Floor

-

0”

Ceiling

-

4”

See Figure 2. The unit may be recessed and rest directly against side studs and the inside surface of the rear wall.

ELECTRICAL ROUGH-IN

Rough in 115 v. wiring, terminating inside the junction box located on top of header plate for recessed, or in a receptacle box (not provided) for flush mount.

Consult local codes or ordinances. See Figure 3.

MODEL NUMBER

AMPS

CF353C, CF354C

1.95

CF503C, CF504C

2.25

CF653C, CF654C

2.25

CF357C

2.2

CF358C

2.25

CF557C

2.5

CF558C

2.55

LOCATION AND SPECIAL PRECAUTIONS

The wall furnace should be located near the center of the house for best heat distribution.

If the area where the appliance is to be installed contains carpeting, tile or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate, wood panel or other non-combustible materials. The use of ceramic or quarry tile is acceptable and will provide a surface that is easily cleaned. This material is to extend the full width and depth of the appliance. If side or rear warm air outlets are being installed, see figure 14 – 18, See page 16 and 17.

4” Minimum

4” Minimum

FIGURE 2

115 V.A.C.

Line

 

In

B-W Vent

 

 

Pipe

2x4 Stud

Header Plate

Wire Nut (not provided)

Switch Box Cover Plate

FIGURE 3

Page 6

Page 6
Image 6
Louisville Tin and Stove CF354C-H, CF504C-H Rough-Ininstructions, Electrical Rough-In, Location And Special Precautions