MAINTENANCE

MAINTENANCE

The entire heater should be checked and cleaned by a qualified service person before the start of each heating season. More frequent cleaning may be required due to excessive lint conditions from carpeting, bedding material, etc.

CABINET

To clean the cabinet and hearth and jamb assemblies of your heater, turn off and allow to cool, then wipe with a soft damp cloth. This will remove any dust. Never use metal polish, furniture wax, or any type of cleaning solution as this could cause odors when the heater is turned back on.

MAIN BURNER

Burners may be cleaned by using a low pressure air hose, or soft brush. Be careful not to damage the ceramic plaque.

 

ODS/PILOT

STEP 1.

Remove bottom front panel.

STEP 2.

Disconnect pilot line from pilot.

STEP 3.

Use a low pressure air hose to blow through pilot and through ODS opening in side of pilot.

WARNING: Never insert anything into any of the openings in the pilot as this could damage the Oxygen Depletion System and expose the homeowner to Carbon Monoxide poisoning.

STEP 3 - PILOT CLEANING

WARNING: After any servicing or cleaning make sure heater is completely re-assembled and check for gas leaks.