Reference Manual R FR 5010 Version1.4

A stud is provided on the termination panel for the connection of an external ground. (Figure 5) Note: the chassis is permanently grounded via the AC connections.

!

!

Caution

Service to be performed by qualified personnel only

Caution

Please remove power before attempting to exchange a power fuse. Only replace the fuse with a correctly rated replacement. For safety DO NOT physically disconnect or isolate the rack from earth for any reason.

Alarm Connection

An external alarm connection is available from the rack. This is a 9 pin SubD male connector. Function and connection information is described below.

 

 

 

 

 

 

 

 

 

 

 

Pin

 

Connection

 

Pin

 

Connection

 

 

 

Number

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

1

 

GND Shield

6

 

N/C

 

 

2

 

Alarm Major

7

 

GPI in A

 

 

3

 

Alarm Minor

8

 

GPI in B

 

 

4

 

Alarm Common

9

GND Shield

 

 

5

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

5

 

 

 

 

9 6

Figure 6. Alarm Connector

Page 17

Page 17
Image 17
Lynx R FR 5010, R FR 5011, Series 5000 Rack Frame manual Alarm Connection, Alarm Connector