Reference Manual R FR 5010 Version1.4
Page 27
Hot Swapping

Power Supplies

The Series 5000 CardModules and Power Supplies
are fully hot swappable in the event of a fault or
failure.

Power Supply Failure

A failure in the Primary power supply will
automatically trigger the use of the redundant
supply (if fitted) and will trigger the following alarm
conditions / indications(requires controller option).
Reported fault on the monitoring system
Alarm GPO trigger on the alarm connector (see
Alarm Connections section)
Front Panel LED (normally green) will go out (See
Alarm / Status indication section)
Once identified, the defective supply can be
removed and replaced with power connected
with no interruption to the operation of the
CardModules.

CardModules

If a CardModule fails the error will be reported over
the monitoring system and via the front side alarm
LED. Alarm function is module dependant so please
refer to the CardModule manual for failure
conditions and indications. The defective
CardModule can be removed and replaced with
an identical replacement without removing power
from the frame.