Reference Manual R FR 5010 Version1.4

Control Connection

An external Control Interface is provided on the rear termination panel. When an R CT 5020 Rack Controller (or R CT 5030 Master Controller) is fitted to the rack this port can be used for two primary functions:

1.When configured as a RS 232 serial port this can be connected directly to a PC running the LYNX control software.

2.When configured for RS 422 operation this port is used to daisy chain other racks fitted with R CT 5020 Rack controllers (up to 15 additional racks)

Note. Please refer to the R CT 5020 Reference Manual for details on how to re-configure the port and more detail on the use of this control interface.

The connection is a 9 pin SubD female connector. Function and connection information is described below.

Connections for RS 422

Pin

 

Connection

 

Pin

 

Connection

 

Number

 

 

Number

 

 

 

 

 

 

 

 

1

GND Shield

6

GND

2

TX A 422

7

TX B 422

3

RX B 422

8

RX A 422

4

GND

9

GND Shield

5

GND

 

 

 

 

Connections for RS 232

Pin

 

Connection

 

Pin

 

Connection

 

Number

 

 

Number

 

 

 

 

 

 

 

 

1

GND Shield

6

GND

2

TX 232

7

 

 

 

3

RX 232

8

 

 

 

4

GND

9

 

GND Shield

5

GND

 

 

 

 