2.Connect three
1.Set the Sample Clock (SETUP:Sync:SClk) to Internal.
2.Set the Sample Rate and Sample Size according to your preference.
Console SettingsSet the 24•8 console to the nominal +4 dBu operating level by setting the five Operating Level switches in the Sub Out and Tape Return sections to the ‘out’ position.
This example describes the hookup for the D8B console equipped for analog I/O.
SDR 24/96
|
| ANALOG OUT 1 - 8 |
|
|
|
| ANALOG OUT 9 - 16 |
|
| ANALOG OUT 17 - 24 |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SDR | 96 | HIGH RESOLUTION |
|
| ANALOG IN 1 - 8 |
|
|
|
| ANALOG IN 9 - 16 |
|
| ANALOG IN 17 - 24 |
| ||||||
|
|
|
|
|
|
|
|
| 24 AUDIO RECORDER | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TRACK/24 BIT DIGITAL | ||
POWER |
| DIGITAL | DIGITAL | DIGITAL | WORD CLOCK I/O | SMPTE | MIDI |
| FOOT | MICRO/ |
| ADAT SYNC | |||||
|
|
|
|
|
|
|
|
|
| IN | OUT | IN | OUT | SWITCH | REMOTE 24 |
| OUT |
| USB |
| 1 - 8 |
| 9 - 16 |
| 17 - 24 | IN | OUT |
|
|
|
|
| CNTRL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| IN | OUT | IN | OUT | IN | OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ADAT SYNC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| IN |
|
|
| X2 |
| X2 |
| X2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CAUTION |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. |
|
|
|
| SERIAL | ||
100 - 240V 250mA |
|
|
|
|
|
|
|
| RISK DO NOT OPEN |
| WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT | SERIAL NUMBER | MANUFACTURING DATE |
| |||
|
|
|
|
|
|
|
|
| NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| OF ELECTRIC SHOCK |
|
|
|
|
| |||
50/60Hz | CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC • WOODINVILLE • WA 98072 • USA |
|
|
| AVIS: RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR |
|
|
|
|
| |||||||
| MADE IN USA • FABRIQUE AU USA • PATENTS PENDING COPYRIGHT ©1998 THE FOLLOWING ARE TRADEMARKS OR |
| REPLACE WITH THE SAME TYPE FUSE AND RATING. | UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. |
|
|
|
|
| ||||||||
| REGISTERED TRADEMARKS OF MACKIE DESIGNS INC.: "MACKIE.", MACKIE DIGITAL SYSTEMS AND THE "RUNNING MAN" FIGURE. |
| DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE | DEBRANCHER AVANT DE REMPLACER LE FUSIBLE |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| ANALOG I/O ANALOG I/O ANALOG I/O |
|
|
|
|
|
| |||
(6) DB25 to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
DB25 Analog |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Cables |
|
|
|
|
|
|
|
| OUTPUT | OUTPUT | OUTPUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INPUT | INPUT | INPUT |
|
|
|
|
|
|
Cables & Hardware |
|
|
|
|
|
|
| TAPE IN/OUTS |
|
| AIO•8 Cards | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Digital 8•Bus |
|
|
|
|
|
|
(3) AIO•8 cards for D8B
(6) DB25 to DB25 analog cables
Hookup
1.Connect three DB25 analog cables between the SDR24/96 Inputs (bottom connector) and the corresponding D8B Tape Outputs (top connector).
2.Connect three DB25 analog cables between the SDR24/96 Outputs (top connector) and the corresponding D8B Tape Inputs (bottom connector).
SDR24/96 Settings
1.Set the Input Type (SETUP:I/O:INPUT TYPE SELECT) to Analog for Inputs
2.Set the Sample Clock (SETUP:Sync:SClk) to Internal.
3.Set the Sample Rate and Sample Size according to your preference. It is not necessary to set the D8B and SDR24/96 to the same Sample Rate, since with analog connections, the sample clocks on the two units are not synchronized
Console Settings
1.Set the D8B Sample Clock to 44.1 k Internal or 48 k Internal according to your preference.
Operation Guide
Guide Operation
13