Soffit Termination
| Attic | |
Duct | Ceiling | |
Termination | ||
|
40’ Max.
Duct Run
Duct
Exterior Wall Termination
Exterior Wall
40’ Max. Duct Run
Rain Cap
Duct Termination | Duct |
|
FP1060
Fig. 7 Typical outside air installations.
Cover Plate
KT143
Fig. 8 Remove outside air cover plate and discard, retain screws.
4.At the termination end, install the duct termination. This should be installed from the outside of the home. Cut a hole in the desired location approxi- mately 4¹⁄₂” (114mm) in diameter, caulk around the hole, and slide the termination through the opening from outside the home. The termination/rain cap
UV36
should be caulked around its perimeter to assure a tight seal. The rain cap opening should be positioned downward. (Fig. 10)
The Outside Air Kit is now installed and ready for use.
KT145
Fig. 9 Secure the inlet collar assembly.
Caulking | Duct Ter- | |
mination | ||
|
Rain
Cap
Wall
FP1061
Fig. 10 Caulk and install duct termination/rain cap in place.
Operating Precautions and Instructions
Operation is automatic. A slight negative pressure inside the house will open the barometric flapper valve.
Periodically inspect the duct termination for any block- age. Correct if necessary.
20007446 | 9 |