P 12/12

Wiring diagram

Models 6412, 6413, M611 (with Variable speed control and Reverse switch)

Important: Do not put slack portion of any Lead wire in the space surrounded by Field and Brush holders. Otherwise Lead wires will be broken by rotating Armature.

Note: 1) Some countries do not use Noise suppressor or Choke coils.

2)Put Choke coils and Noise suppressor (if used) in place as illustrated in Fig. D-6.

3)Choke coil (with blue Lead wire and black Lead wire) is reversible when connected to Switch.

Fig. D-6

Lead wires

Choke coil lead wire (purple) to Brush holder

Choke coil lead wire (purple) to No.4 Terminal of Switch

Choke coil lead wire (orange) to Brush holder

Choke coil lead wire (orange) to No.3 Terminal of Switch

Field lead wire (black) to No.2a Terminal of Switch

Field lead wire (white) to No.5 Terminal of Switch

Choke coil lead wire (blue or black) to No.6 Terminal of Switch

Brush holder

See "Connecting Lead wire to Brush holder".

Fix two Lead wires with this Lead wire holder.

Choke coil

(with purple Lead wires) [if used]

Put slack portion of Lead wire in the space between Brush holder and inside wall of Housing (L). Otherwise the Lead wire will touch rotating Armature.

Put slack portion of Lead wires in this space.

boss A boss B

Field

See "Connecting Lead wire to Brush holder".

Route Lead wires between these ribs.

Choke coil (with orange Lead wires) [if used]

Choke coil (with blue Lead wire and black Lead wire)

[if used]

Switch

Route Lead wires under Brush holder.

Noise suppressor [if used]

Power supply cord

Connecting Lead wire to Brush holder 1) Brush holders are not reversible

when assembled to Housing (L). Terminal insertion hole of each Brush holder must be positioned

outside boss A/boss B.

boss A

Terminal

Brush holder

2) Do not route each Lead wire

inside boss A/boss B.

boss B

Page 12
Image 12
Makita M611, 6412, 6413 Brush holder See Connecting Lead wire to Brush holder, Choke coil With purple Lead wires if used