Makita M611 P 12/12, Fig. D-6, Choke coil lead wire purple to No.4 Terminal of Switch, Lead wires

Models: 6412

1 12
Download 12 pages 63.05 Kb
Page 12
Image 12
P 12/12

P 12/12

Fig. D-6 Wiring diagram

Models 6412, 6413, M611 (with Variable speed control and Reverse switch)

Important: Do not put slack portion of any Lead wire in the space surrounded by Field and Brush holders. Otherwise Lead wires will be broken by rotating Armature.

Note: 1) Some countries do not use Noise suppressor or Choke coils.

2)Put Choke coils and Noise suppressor (if used) in place as illustrated in Fig. D-6.

3)Choke coil (with blue Lead wire and black Lead wire) is reversible when connected to Switch.

Fig. D-6

Lead wires

 Choke coil lead wire (purple) to No.4 Terminal of Switch Choke coil lead wire (purple) to Brush holder

 Choke coil lead wire (orange) to No.3 Terminal of Switch Choke coil lead wire (purple) to No.4 Terminal of Switch

 Field lead wire (white) to No.5 Terminal of Switch Choke coil lead wire (orange) to Brush holder

Choke coil lead wire (blue or black) to No.6 Terminal of Switch Choke coil lead wire (orange) to No.3 Terminal of Switch

Field lead wire (black) to No.2a Terminal of Switch

Brush holder Field lead wire (white) to No.5 Terminal of Switch

Choke coil lead wire (blue or black) to No.6 Terminal of Switch

Brush holder

See "Connecting Lead wire to Brush holder".

Fix two Lead wires Choke coil  (with orange Lead wires) [if used] Noise suppressor [if used] with this Lead wire holder.

Choke coil

(with purple Lead wires) [if used]

Put slack portion of Lead wire Manual background in the space between Brush holder and inside wall of Housing (L). Otherwise the Lead wire will touch rotating Armature.

Put slack portion of Lead wires Manual backgroundManual backgroundManual background in this space.

boss A Manual background boss B Manual background

Field

See "Connecting Lead wire to Brush holder".

Route Lead wires Manual backgroundManual backgroundManual backgroundManual background between these ribs.

Choke coil Manual backgroundManual backgroundManual background (with orange Lead wires)Manual background [if used] Manual backgroundManual background

Choke coil (with blue Lead wire and black Lead wire)

[if used]

Switch

Route Lead wiresManual backgroundManual backgroundManual background under Brush holder.

Noise suppressor [if used]

Power supply cord

Connecting Lead wire to Brush holder 1) Brush holders are not reversible

when assembled to Housing (L). Terminal insertion hole of each Brush holder must be positioned

outside boss A/boss B.

boss A

Terminal

Brush holder

2) Do not route each Lead wire

inside boss A/boss B.