Manitowoc Ice S1000M Guardian, Sachet Installation/Replacement Procedure, Screw Location, Section

Models: S1000M

1 38
Download 38 pages 21.14 Kb
Page 24
Image 24
Guardian™

Maintenance

Section 4

 

 

Guardian™

Slime is a leading cause of ice machine breakdowns and biological growth is a health concern. The Guardian™ system releases chlorine dioxide on a controlled basis to inhibit the growth of bacteria and fungi that form slime and cause malodors in the food zone of ice machines.

The Guardian™ will not control mineral or other water borne buildup. Your water quality will determine the length of time before mineral buildup affects ice machine performance. Mineral buildup must be removed as often as necessary to ensure trouble-free operation of the ice machine.

The Guardian™ sachet holder is included with the sachet packets. Refer to installation/replacemnet procedure to install/change sachet holder/packet.

SACHET INSTALLATION/REPLACEMENT PROCEDURE

1. Loosen the front panel screws and remove panel.

Inside Left

Loosen

Screw

Front Door

 

Guardian

Guardian™ Location

GUARDIAN™ SACHET REPLACEMENT

FREQUENCY

Sachet packet(s) require replacement every thirty (30) days or whenever they come in direct contact with water. Refer to chart below for requirements.

Ice Machine

Sachet Use

S1000M

1 or 2*

*Although one sachet is recommended, extreme conditions may necessitate using two sachet packets.

Guardian™ sachet packets are available through your local Manitowoc ice machine dealer.

Screw Location

2.Inside the front panel there are two thumbscrew holes covered by stickers, pierce the sticker with a screwdriver.

3.Attach the sachet holder to the front panel by inserting the thumbscrews through the holes in the sachet holder and tighten the thumbscrews.

4.Remove the new sachet packet from foil package and install into holder. Removing the foil package allows moisture in the air to activate the sachet contents.

5.Replace the front panel and tighten the screw.

6.Discard the use sachet packet in the trash.

CLEAN UP PROCEDURE FOR DAMAGED SACHET PACKET

1.Remove all ice from bin/dispenser and discard.

2.Initiate a cleaning and sanitizing sequence on the ice machine (see next pages).

3.Clean the bin/dispenser. Flush the drain thoroughly to prevent future drain blockage.

4.Sanitize the bin/dispenser.

5.Install a replacement sachet packet and reinstall all panels.

4-2

Part Number 80-1561-3

Page 24
Image 24
Manitowoc Ice S1000M manual Guardian, Sachet Installation/Replacement Procedure, Screw Location, Maintenance, Section