INSTALLATION
DURA-VENT
HORIZONTAL
INSTALLATIONS
1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.
2)Direct Vent pipe and fi ttings are designed with special
Diagram 1: Hint: Apply silicone to female end.
b)Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose.
c)Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
*As specifi ed in CGA B149 Installation Code.
Local codes or regula- tions may require differ- ent clearances.
Below Grade Snorkel Installation
If the Snorkel Termination must be installed below grade, i.e. basement application, properdrainagemustbeprovidedtoprevent waterfromenteringtheSnorkelTermination. Refer to
3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 10" x 10" (inside dimensions) square hole. The center of the square hole should line up with the centerline of the horizontal pipe, as shown in diagram 3. Cut and frame the 10 inch square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is
Diagram 2 |
Note:
a)
fittings, are designed to slide straight onto the male ends of adjacent pipes and fi ttings, by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends (Diagram 1). Push the pipe sections
completely | together, then |
| |
one section | clockwise approximately |
| |
| |||
are fully locked. The female locking lugs |
| ||
will not be visible from the outside on |
| ||
the Black Pipe or fi ttings. They may be |
| ||
located by examining the inside of the |
| ||
female ends.Apply sealant |
| ||
innerpipeandhightempsiliconesealant | Diagram 2a | ||
to outer pipe on every | |||
|
Hampton® H35 Direct Vent Freestanding Gas Stove | 21 |