Hampton Direct H35-NG1 Installation, Locating Your, Gas Stove, Combustion And, Ventilation Air

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 8
Image 8
LOCATING YOUR

INSTALLATION

 

LOCATING YOUR

 

 

 

 

 

OPTIONAL FAN INSTALLATION

 

 

 

 

 

 

 

 

 

GAS STOVE

Fan Kit Contains:

7) Install locking grommet to power cord and

When selecting a location for your stove, ensure

 

 

 

 

 

 

 

 

 

 

 

 

 

Qty.

Description

push through hole in the rear panel and give

that the clearances listed above are met as well

1

 

Fan Speed Controller with nut, and

a 1/4 turn to secure.

as ensuring that there is adequate accessibility

 

 

knob.

 

 

 

for servicing and proper operation.

1

 

Fan Assembly c/w green wire

NOTE: When running wires, keep them clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

attached

ofvalveassemblyandtubingtoavoid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Power cord

tangling of wires and valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Plastic locking grommet

NOTE: Becarefulnottocutwireswhenpass-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

Remove the Top Control Panel Assembly

ing through holes in the firebox.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by removing the three screws. Diagram 1.

8) Rungreengroundwirefromfanandconnect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to grounding lug.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A)

Cross Corner

 

 

 

B)

Room Divider

 

 

 

C)

Island

 

 

 

D)

Flat on Wall

 

Diagram 1

 

E) Flat on Wall Corner

 

 

 

 

 

F)

Flush with Wall/Alcove

2) Remove the nylon hole plug from the control

 

 

 

 

For Vent Termination requirements, see the

 

panel.

9) Connect green power cord ground wire to

 

 

"Exterior Vent Terminal Locations" section.

3)

Install the fan speed controller onto the

grounding lug.

 

 

 

 

 

 

control panel and secure with nut. Connect

10) Run the neutral black wire from power cord

 

 

 

remaining wire harness wires to speed

 

 

 

and connect to fan motor.

 

 

 

control. NOTE: Speed control wires must

 

MANUFACTURED

 

11) Run the live black wire from power cord and

 

 

be in the down position when control panel

 

 

 

 

 

MOBILE HOME

 

is in place.

connect to speed control wire.

 

 

 

 

4) Push black knob onto speed control.

 

 

ADDITIONAL

12) Connect the white wire of the wire harness

 

 

 

 

 

 

 

 

REQUIREMENTS

5) Remove the rear access panel on the back

to the fan terminal.

 

 

 

 

of the stove by removing the 6 screws. Install

NOTE: Pull excess wire next to fan to

 

 

 

the fan onto pins as per Diagram 2.

1) Ensure that structural members are not cut

 

avoid excessive heat from the firebox.

 

 

 

or weakened during installation.

 

 

 

 

 

13) Ensure all wires are pulled away from firebox

2) Ensure proper grounding using the #8

 

to avoid excessive heat and secure with

ground lug provided.

 

stick-on wire clip.

3) Appliance must be anchored to the fl oor

 

14) Re-attach control panel with 3 screws, re-

with the supplied anchoring methods.

 

versing step 1. Re-attach rear access panel

 

 

with 6 screws, reversing step 5.

COMBUSTION AND

 

NOTE:Whenpowercordispluggedin,speed

 

control is in the ON position and stove is

VENTILATION AIR

 

burning, allow 10 - 15 minutes for the ther-

 

 

 

Diagram 2

modisc (temperature switch) to activate and

The combustion air from this appliance is drawn

 

turn on the Fan automatically.

 

 

from outside the building through the outer fl ue.

NOTE: Do NOT damage, cut or remove

WARNING:

Extra provision for combustion air inside the

room is not required.
the 3" aluminum air intake pipes.
Electrical Grounding Instructions

 

 

Hint for pushing fan down onto pins - rub a
This appliance is equipped with

 

bit of dish soap on the pins so the grommets

a three pronged (grounding) plug

 

will slide down more easily. Check to make
for your protection against shock

 

sure the fan is seated properly on the pins
hazard and should be plugged

 

- try to move the fan back and forth.

 

6) Push power cord through hole in the rear

directly into a properly grounded

 

three-prong receptacle. Do not cut

 

panel 14" - 16" and tie a loose knot in the

or remove the grounding prong

 

cord on the inside to prevent the power cord

from this plug.

 

from being pulled out. Diagram 2.

8

Hampton® H35 Direct Vent Freestanding Gas Stove

Page 8
Image 8
Hampton Direct H35-NG1 Locating Your, Gas Stove, Combustion And, Ventilation Air, Optional Fan Installation, Diagram