INSTALLATION
7) Attach the Piezo ignition wire to the DC | 11) Attach the DC sparker generator wires to |
Sparker. | the DC sparker. |
Piezo
Ignitor
Installation of the DC Sparker
for the P90 Units Only:
1)Locate the Piezo Ignitor situated at the side of valve.
Piezo
Ignitor
8)Insert both the ground wire and the DC sparker generator wire through the hole of the DC spark heat shield.
12)Install the supplied battery into the DC Sparker Box by opening the battery compartment.
NOTE: The battery in the DC Sparker Box will need to be replaced annually.
Battery
Compartment
2)Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket.
Ignitor
Wire
Piezo
Ignitor
9)Install the plastic bushing over the outside of the hole.
10)Attach the ground wire to the DC spark mounting bracket.
13)Attach the heat shield to the DC sparker, then mount this onto the stove.
Note: We recommend attaching the DC sparker box to the bottom rear of the stove (or place this in a convenient location, away from the heat source).
14)Tie up the loose wire with the wire clip.
3)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.
DC
Sparker
Ignitor
Wire
4)Install the 3/4" nylon plug to cover up the hole on the mounting bracket.
Hampton® H35 Direct Vent Freestanding Gas Stove | 29 |