INSTALLATION

10)Adjust Vent restrictor setting: To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictorplatetothecorrectposition.Tighten the screws.

Unit

 

 

 

Btu/h

Restrictor Opening

H35

NG

30,000

A

1-3/4" (45mm)

H35

LP

28,500

A

1-3/4" (45mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4)Beforeinstallingthesidebrickpanels,loosen the screws for the brick tabs enough so that you can slide the brick tabs on to the screws easily but that the tabs are secure. For the location of the side brick tab screws see Diagram 1.

Brick

tab screw

Back

brick

panel

Side

brick

panel

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-43 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e)02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)Embers

i)Lava

A) 02-43

D) 02-46 G) 02-48

Vent Restrictor setting at Low Btufor Straight Horizontal Venting

11)Attach the label "This unit has been con- verted to..." on top of the Serial # decal over the higher Btu information.

12)Check for gas leaks.

13)Check inlet and outlet pressures.

14)Check operation of fl ame control. Check for proper fl ame appearance and glow on logs.

Diagram 1

5)Put the side panels in next. Slide them in from the front and push them fl at up against the wall. Be very careful not to scratch them on the fi rebox hardware.

LeftRight

SideSide

PanelPanel

C) 02-44 B) 02-56 F) 02-47

E) 02-45

The "02" refer numbers (i.e. 02-43) aremolded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

OPTIONAL

BRICK PANEL

1)Remove the cast top and glass front (see Glass Replacement section in this manual for instructions).

2)Remove the log set if installed.

3)Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket.

Back Panel

6)Install the brick tabs (refer to Diagram 2).

Brick

Brick Tab

Tab

Screw

 

Diagram 2

2)Lift off the Cast Top and remove the glass front (refer to the "Glass Replacement" section in this manual).

3)Sprinkle the embers on the left and right sides of the fi rebox base.

EmbersEmbers