Hampton Direct H35-NG1, H35-LP1 Installation, Dura-Venttermination Kit, Alternate, Horizontal

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 20
Image 20
DURA-VENT TERMINATION KIT

INSTALLATION

DURA-VENT TERMINATION KIT

Planning Your Dura-Vent

Installation

There are two basic types of Dura-Vent Direct Vent Systeminstallations: horizontal termination and vertical termination. Confi rm the maximum horizontalrunandmaximumverticalrisefromthe diagrams in the "Venting Arrangment" section.

When planning your installation, it will be nec- essary to select the proper length of vent pipe for your particular requirements. For horizontal installations, determine the minimum clearance from the rear of the unit to the wall. It is also important to note the wall thickness. (The wall

thimble is suitable for 2 x 4 or 2 x 6 wall construc- tion.) Select the amount of vertical rise desired for "vertical-to-horizontal" type installations.

Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

The minimum clearance requirements between the outer wall of the vent pipe and nearby com- bustible surfaces is 1-1/4 inch. Be sure to check the vent termination clearance requirements from

decks,windows,soffits,gasregulators,airsup- ply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section and in your local building codes.

To determine the length of vent pipe required for vertical installations, measure the distance from the unit flue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second storey, and allow for suffi cient vertical height above the roof line.

For multi-storey applications, fi re stops are required at each fl oor level. If an offset is needed, additional pipe, elbows and supports will be required.

Donotexceedthemaximumnumberofelbows. One 90o for horizontal terminations and two 45o for vertical termination.

Dura-Vent Basic

Horizontal Kit # 970

190o Elbow

1Wall Thimble Cover

1Horiz. Sq. Term. Cap

Alternate

Horizontal

Termination Caps

20

Hampton® H35 Direct Vent Freestanding Gas Stove

Page 20
Image 20
Hampton Direct H35-NG1, H35-LP1 Dura-Venttermination Kit, Planning Your Dura-Vent Installation, Alternate, Horizontal